We are not experts or professionals in any field. Any advice or information found on this website should not be considered as 100% accurate and is provided on an AS-IS basis. Use any information you find here at your own risk. Click here and carefully read and agree to the DISCLAIMER statements before using any information found on this website. Compressor Kicks Out When Adding Freon - Solution
Written by Ronnie Friday, 29 July 2011 If the freon charge drops too low in the A/C system, the low pressure switch signals the BCM
to lock-out the compressor to prevent damage from running with a low
charge. When this happens a code B447 and/or B448 will be set and warning message will be displayed in the IPC. The only way to get the compressor to run again is to clear the
codes. The best way to clear these codes is by disconnecting the negative battery cable for about a minute and then reconnect. Before attempting to add freon again do the following:
The following instructions are only intended to keep the compressor running temporarily while filling the system that is low on freon. This procedure should not be used for any other reason! Damage to the system could result from misuse. The best way to keep the compressor engaged is to remove the connector from the Low Pressure Switch and place a jumper between the two terminals in the connector. Then clear the codes by removing the battery cable as described above and the compressor should continue running long enough to fill the system with freon.The following photo shows the location of the Low Pressure Switch. You will need to remove the plastic cowl cover to see it. Note that it is located in the large AC line. Don't confuse it with the Low side Temperature Sensor. When you have the connector removed, there will be only two wires in the connector. Just putt a short wire (large paperclip) between those terminals. (No need to apply 12 volts from an external source.) Then reset the codes by removing the battery cable and the compressor should run while you install the freon. Don't forget to remove the jumper and replace the connector on the Low Pressure Switch when you're done. ![]() In some situations the above procedure may not work. If that is the case jump 12V directly to the clutch from the battery (easiest to do at the relay socket). Caution should be used when applying 12 volts directly to the compressor. Never attempt to attach the jumper with the engine running. Last Updated Friday, 09 September 2011
IMPORTANT NOTICE: We are not experts or professionals in any field. Any advice or information found on this website should not be considered as 100% accurate and is provided on an AS-IS basis. Use any information you find here at your own risk. Click here and carefully read and agree to the DISCLAIMER statements before using any information found on this website. |
Help Support UsYour donation to help support the services this website provides is appreciated.
Latest Tips and Tutorials |







(Comments must be approved by the website administrator before they are published)